    KFD0-SCS-Ex1.55倍加福

  • 所属行业:电气 电工仪器仪表 传感器
  • 发布日期:2020-04-11
  • 阅读量:214
  • 价格:34.00 元/台 起
  • 产品规格:KFD0-SCS-Ex1.55倍加福
  • 产品数量:54.00 台
  • 包装说明:KFD0-SCS-Ex1.55倍加福
  • 发货地址:上海松江方松松云水苑社区  
  • 关键词:KFD0-SCS-Ex1.55倍加福

    KFD0-SCS-Ex1.55倍加福详细内容

    KFD0-HMS-16倍加福安全栅KFD0-SCS-Ex1.55倍加福
    HART Multiplexer Slave
    16-channel, No external power required, HART field device input (revision 5 to 7), Used with HART Multiplexer Master KFD2-HMM-16, Up to SIL 3 acc. to IEC 61508
    
    KFD0-RO-Ex2
    Relay Module
    2-channel isolated barrier, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SCS-Ex1.55
    SMART Current Driver/Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex protection, Transfer direction: to the field / to the control system
    
    KFD0-SD2-Ex2.1045
    Solenoid Driver
    2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD2-CRG2-Ex1.D
    Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-EB2.R4A.B
    Redundant Power Feed Module
    Interface for Power Rail, Used for redundant configuration, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication
    
    KFD2-GUT-Ex1.D
    Temperature Converter with Trip Values
    1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-HMM-16
    HART Multiplexer Master
    16-channel, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7), Up to 15 KFD0-HMS-16 slave units can be connected, Up to SIL 3 acc. to IEC 61508
    
    KFD2-SCD2-Ex1.LK
    SMART Current Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-SCD2-Ex2.LK
    SMART Current Driver
    2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-SL2-Ex2.B
    Solenoid Driver
    2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SOT3-Ex1.LB
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SOT3-Ex2
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-1
    SMART Transmitter Power Supply
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-1.2O
    SMART Transmitter Power Supply
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, Up to SIL 3 acc. to IEC 61508
    
    KFD2-STC5-Ex1
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-Ex1.2O
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, Up to SIL 3 acc. to IEC 61508
    
    KFD2-STC5-Ex2
    SMART Transmitter Power Supply
    2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-UFC-Ex1.D
    Frequency Converter with Trip Values
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-USC-1.D
    Signal Converter with Trip Value
    1-channel ** conditioner, 24 V DC supply (Power Rail), Scaleable current or voltage input, Current or voltage output, Relay contact output, Configurable by keypad, Line fault detection (LFD)
    
    KFD2-UT2-Ex1
    Universal Temperature Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-UT2-Ex2
    Universal Temperature Converter
    2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as ** splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-VR4-Ex1.26
    Voltage Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... -20 V, Vibration sensor inputs, Voltage/current field supply, Voltage output 0 V ... -20 V, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the control system
    
    KFD0-CC-1
    Current/Voltage Converter
    1-channel ** conditioner, 24 V DC supply (loop powered), Current or voltage input, Output: 4 ... 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD)
    
    KFD0-CC-Ex1
    Current/Voltage Converter
    1-channel isolated barrier, 24 V DC supply (loop powered), Current or voltage input, Output: 4 ... 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD)
    
    KFD0-CS-Ex1.50P
    Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-CS-Ex1.51P
    Current Driver/Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-CS-Ex1.54
    Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC 61508, Transfer direction: to the control system
    
    KFD0-CS-Ex2.51P
    Current Driver/Repeater
    2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-RSH-1.4S.PS2
    Relay Module
    1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 26.5 V DC, non-polarized, Fail-safe relay contact output for de-energized and energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SCS-1.55
    SMART Current Driver/Repeater
    1-channel ** conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-SD2-Ex1.10100
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 100 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SD2-Ex1.1180
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 80 mA at 11 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SD2-Ex2.1245
    Solenoid Driver
    2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD0-TR-1
    RTD Converter
    1-channel ** conditioner, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection
    
    KFD0-TR-Ex1
    RTD Converter
    1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection
    
    KFD2-BR-1.PA.1500
    Basic Segment Coupler
    Output: 24 ... 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting
    
    KFD2-CD-1.32
    Current Driver
    1-channel ** conditioner, 24 V DC supply (Power Rail), Current input 0 mA ... 20 mA, Current output 0 mA ... 20 mA, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CD-Ex1.32
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Accuracy 0.1 %, Current input 0 mA ... 20 mA, Current output 0 mA ... 20 mA, 1-channel isolated barrier, 24 V DC supply (Power Rail), Factory configured input/output, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CRG2-1.D
    Transmitter Power Supply
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-DWB-1.D
    Rotation Speed Monitor
    1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 12 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-DWB-Ex1.D
    Rotation Speed Monitor
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-EB2
    Power Feed Module
    Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication
    
    KFD2-ER-1.6
    Conductivity Switch Amplifier
    1-channel ** conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Relay contact output, Minimum/maximum control
    
    KFD2-ER-Ex1.W.LB
    Conductivity Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)
    
    KFD2-GS-1.2W
    Current/Voltage Trip Value
    1-channel ** conditioner, 24 V DC supply (Power Rail), Current and voltage input, 2 relay contact outputs, Programmable high/low alarm, Configurable via DIP switches and potentiometer, Terminal blocks with test sockets
    
    KFD2-GUT-1.D
    Temperature Converter with Trip Values
    1-channel ** conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-HLC-Ex1.D
    HART Loop Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as ** splitter (1 input and several outputs), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad
    
    KFD2-PT2-Ex1
    Potentiometer Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508
    
    KFD2-PT2-Ex1-5

    http://chuangfusy.b2b168.com
    欢迎来到上海创弗实业有限公司网站, 具体地址是上海市松江区方松街道辰塔路2号,联系人是张晓龙。 主要经营上海创弗实业有限公司,公司业务范围涉及:工厂自动化产品销售、过程自动化控制仪表,阀门,仪器仪表,传感器,安全栅,技术咨询、技术服务,承接过程仪表控制项目罗斯蒙特ROSEMOUNT变送器, 液位产品系列罗斯蒙特分析仪变送器和传感器施克/西克SICK传感器、倍加福P+F安全栅,倍加福传感器,IFM易福门传感器,TURCK图尔克传感器,FESTO费斯托,MTS传感器等自动化产MTL安全栅。 单位注册资金单位注册资金人民币 100 万元以下。 价格战,是很多行业都有过的恶性竞争,不少厂家为了在价格战役中获胜,不惜以牺牲产品质量为代价,而我们公司坚决杜绝价格战,坚持用优质的原材料及先进的技术确保产品质量,确保消费者的合法利益。