    KFD2-DU-Ex1.D倍加福

  • 所属行业:电气 电工仪器仪表 传感器
  • 发布日期:2020-04-11
  • 阅读量:211
  • 价格:34.00 元/台 起
  • 产品规格:KFD2-DU-Ex1.D倍加福
  • 产品数量:34.00 台
  • 包装说明:KFD2-DU-Ex1.D倍加福
  • 发货地址:上海松江方松松云水苑社区  
  • 关键词:SGD7S-590A00A

    KFD2-DU-Ex1.D倍加福详细内容

    KFD0-RSH-1.1E.1
    Relay Module
    1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
    
    KFD0-TT-Ex1
    Thermocouple Converter
    1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges
    
    KFD2-BR-Ex1.3PA.93
    Segment Coupler 1
    Output: 12.6 ... 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator
    
    KFD2-CD-Ex1.32-1
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Current input 4 mA ... 20 mA, Current output 0 mA ... 20 mA, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CD-Ex1.32-10
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Current input 4 mA ... 20 mA, Voltage output 0 V ... 5 V, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CD-Ex1.32-12
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Current input 0 mA ... 20 mA, Voltage output 0 V ... 10 V, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CD-Ex1.32-13
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Current input 4 mA ... 20 mA, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CD-Ex1.32-15
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Voltage input 0 V ... 10 V, Voltage output 0 V ... 10 V, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CD-Ex1.32-2
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Current input 0 mA ... 20 mA, Current output 4 mA ... 20 mA, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CD-Ex1.32-3
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Voltage input 0 V ... 5 V, Current output 0 mA ... 20 mA, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CD-Ex1.32-5
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Voltage input 0 V ... 5 V, Current output 4 mA ... 20 mA, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CD-Ex1.32-6
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Voltage input 0 V ... 10 V, Current output 0 mA ... 20 mA, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CD-Ex1.32-8
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Voltage input 0 V ... 10 V, Current output 4 mA ... 20 mA, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-DU-Ex1.D
    Switch Amplifier, Timer Relay
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
    
    KFD2-EB2.R4A.B.SP
    Redundant Power Feed Module
    Interface for Power Rail, Used for redundant configuration, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication, Connection via spring terminals with push-in connection technology
    
    KFD2-EB2.SP
    Power Feed Module
    Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication, Connection via spring terminals with push-in connection technology
    
    KFD2-ELD-Ex16
    Ground Fault Detection
    16-channel isolated barrier, 24 V DC supply (Power Rail), Analog or digtial field device inputs, Monitors leakage current, Fault relay contact output, LED status indication, Test circuit for validation, Parallel connection for easy integration, Conformal coating
    
    KFD2-ER-1.5
    Conductivity Switch Amplifier
    1-channel ** conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Relay contact output, Minimum/maximum control
    
    KFD2-ER-1.W.LB
    Conductivity Switch Amplifier
    1-channel ** conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)
    
    KFD2-HLC-Ex1.D.4S
    HART Loop Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as ** splitter (1 input and several outputs), 4 relay contact outputs (NO contact), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad
    
    KFD2-PT2-Ex1-6-Y112844
    Potentiometer Converter
    1-channel, 24 V DC supply (Power Rail), Potentiometer input, Current output 0 mA ... 24 mA, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508
    
    KFD2-PT2-Ex1-Y98312
    Potentiometer Converter
    1-channel, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SL-4
    Solenoid Driver, Power Amplifier
    4-channel ** conditioner, 24 V DC supply (Power Rail), Output 600 mA per channel, Logic inputs, Common safety-oriented disable input, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Output rated operating current: 600 mA per channel , sustained short-circuit proof and overload-proof
    
    KFD2-SOT3-Ex1.LB.IO
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SOT3-Ex2.IO-Y1
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SR2-2.W.SM
    Standstill and Rotational Direction Monitor
    2-channel ** conditioner, 24 V DC supply, PNP/push-pull, dry contacts or NAMUR inputs, Selectable frequency trip values, 2 relay contact outputs, Start-up override, Selectable mode of operation, Without line fault detection, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SR3-2.2S
    Switch Amplifier
    2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-STC5-Ex1.2O.H
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, High field voltage 17 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD2-STV4-Ex1-2
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/2 V ... 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STV4-Ex2-1
    SMART Transmitter Power Supply
    2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/1 V ... 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STV4-Ex2-2
    SMART Transmitter Power Supply
    2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/2 V ... 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STV5-Ex1-1
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/1 V ... 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-UFT-2.D
    Frequency Converter with Direction and Synchronization Monitor
    2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD)
    
    KFD2-UT2-Ex2-1
    Universal Temperature Converter
    2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as ** splitter (1 input and 2 outputs), Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-VR-Ex1.12
    Voltage Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 9 V, Voltage output 0 V ... 9 V, Transfer direction: to the control system
    
    KFD2-VR-Ex1.19
    Voltage Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V ... 10 V, Voltage output -10 V ... 10 V, Transfer direction: to the control system
    
    KFD2-VR-Ex1.19-Y109129
    Voltage Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V ... 10 V, Transmission frequency up to 50 kHz, Voltage output -10 V ... 10 V, Transfer direction: to the control system
    
    KFD2-VR2-Ex1.500M
    Voltage Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV ... ± 500 mV, Voltage output 0 mV ... ± 500 mV, Selectable up/downscale sensor breakage detection, Transfer direction: to the control system
    
    KFD2-WAC2-Ex1.D-Y1
    Strain Gauge Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware or keypad, RS-485 interface, Low response time, Line fault detection (LFD)
    
    KFD2-CD-Ex1.32-21
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Voltage input 0 V ... 10 V, Voltage output 0 V ... 5 V, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CD-Ex1.32-9
    Current/Voltage Driver
    Current and voltage input, Current or voltage output, Factory configured input/output, Current input 0 mA ... 20 mA, Voltage output 1 V ... 5 V, 1-channel isolated barrier, 24 V DC supply (Power Rail), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD0-RSH-1
    Relay Module
    1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 16 V DC ... 30 V DC, non-polarized, Fail-safe relay contact output, Up to SIL 3 acc. to IEC 61508
    
    KFD0-RSH-1-Y2
    Relay Module
    1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 30 V DC, non-polarized, Fail-safe relay contact output, Test pulse immunity, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SD2-Ex1.1045
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SD2-Ex1.1065
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 65 mA at 9.8 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD2-SL2-Ex1
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-SL2-Ex1.B
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SL2-Ex1.LK
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.2 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-SOT2-Ex1.LB
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    KFD2-SOT2-Ex2
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SOT2-Ex2.IO
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SR2-2.2S
    Switch Amplifier
    2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-SR2-Ex2.2S
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-ST2-Ex1.LB
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Active fault output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-ST2-Ex2
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC4-Ex1
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC4-Ex1-Y1
    SMART Transmitter Power Supply, Output Current Sink
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC4-Ex1.2O
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
    
    KFD2-STC4-Ex1.2O.H
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Terminal blocks with test sockets, High field voltage 17.6 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD2-STC4-Ex1.H
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA, Terminals with test points, High field voltage 17.6 V DC, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC4-Ex2
    SMART Transmitter Power Supply
    2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA ... 20 mA, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STV4-Ex1-1
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/1 V ... 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-FF-Ex2.RS232
    RS 232 Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), RS 232 input/output, Transfer direction: to the control system
    
    KFD2-SL2-Ex1.LK-Y1
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Increased input load, Output 45 mA at 11.2 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-SL2-Ex1.LK.1045
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 10 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-SOT2-Ex2.IO-Y181008
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation
    
    KFD2-STV4-Ex1.2O-2
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/2 V ... 10 V, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
    
    KFD2-UT2-1-1
    Universal Temperature Converter
    1-channel ** conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-UT2-2-1
    Universal Temperature Converter
    2-channel ** conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as ** splitter (1 input and 2 outputs), Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD0-CS-1.50
    Repeater
    1-channel ** conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SCD-Ex1.LK
    SMART Current Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-SH-Ex1.T
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply, Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
    
    KFD2-SH-Ex1.T.OP
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
    
    KFD2-SR2-Ex1.W
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-SR2-Ex1.W.LB
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-SR2-Ex2.W
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD0-CS-2.50
    Repeater
    2-channel ** conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508
    
    KFD0-CS-2.51P
    Current Driver/Repeater
    KFD2-SOT2-Ex1.LB.IO
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508

    http://chuangfusy.b2b168.com
    欢迎来到上海创弗实业有限公司网站, 具体地址是上海市松江区方松街道辰塔路2号,联系人是张晓龙。 主要经营上海创弗实业有限公司,公司业务范围涉及:工厂自动化产品销售、过程自动化控制仪表,阀门,仪器仪表,传感器,安全栅,技术咨询、技术服务,承接过程仪表控制项目罗斯蒙特ROSEMOUNT变送器, 液位产品系列罗斯蒙特分析仪变送器和传感器施克/西克SICK传感器、倍加福P+F安全栅,倍加福传感器,IFM易福门传感器,TURCK图尔克传感器,FESTO费斯托,MTS传感器等自动化产MTL安全栅。 单位注册资金单位注册资金人民币 100 万元以下。 价格战,是很多行业都有过的恶性竞争,不少厂家为了在价格战役中获胜,不惜以牺牲产品质量为代价,而我们公司坚决杜绝价格战,坚持用优质的原材料及先进的技术确保产品质量,确保消费者的合法利益。