企业信息

    上海创弗实业有限公司

  • 6
  • 公司认证: 营业执照已认证
  • 企业性质:外资企业
    成立时间:
  • 公司地址: 上海市 松江区 方松街道 泰晤士小镇社区 辰塔路2号
  • 姓名: 张晓龙
  • 认证: 手机已认证 身份证未认证 微信已绑定

    KFD2-SOT3-Ex2.IO倍加福

  • 所属行业:电气 电工仪器仪表 传感器
  • 发布日期:2020-04-11
  • 阅读量:249
  • 价格:34.00 元/台 起
  • 产品规格:KFD2-SOT3-Ex2.IO倍加福
  • 产品数量:45.00 台
  • 包装说明:KFD2-SOT3-Ex2.IO倍加福
  • 发货地址:上海松江方松松云水苑社区  
  • 关键词:KFD2-SOT3-Ex2.IO倍加福

    KFD2-SOT3-Ex2.IO倍加福详细内容

    
    KFD2-RCI-Ex1
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Output 20.4 mA at 13.5 V DC, 19 V DC ... 30 V DC input, Line fault detection (LFD), Conformal coating, Up to SIL 3 acc. to IEC 61508
    
    KFD2-RSH-1.2D.FL2
    Relay Module
    1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
    
    KFD2-RSH-1.2D.FL3
    Relay Module
    1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
    
    KFD2-RSH-1.2E.L2
    Relay Module
    1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508
    
    KFD2-RSH-1.2E.L3
    Relay Module
    1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508
    
    KFD2-SH-Ex1
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
    
    KFD2-SL2-Ex2
    Solenoid Driver
    2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-SLD-Ex1.13100
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Logic input, Output 100 mA at 13 V DC, Alternating outputs for the operation of solenoids with 2 coils, High output power for IIB gas group, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC 61508
    
    KFD2-SOT3-Ex2.IO
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SR2-Ex1.W
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Up to SIL 2 acc. to IEC/EN 62061 , Up to PL d acc. to EN/ISO 13849
    
    KFD2-SR2-Ex1.W.LB
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Up to SIL 2 acc. to IEC/EN 62061 , Up to PL d acc. to EN/ISO 13849
    
    KFD2-SR2-Ex2.W
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Up to SIL 2 acc. to IEC/EN 62061 , Up to PL d acc. to EN/ISO 13849
    
    KFD2-SR3-Ex2.2S
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-SRA-Ex4
    Switch Amplifier
    4-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 50 % less wiring, 2:1 technology, Relay contact output, Line fault detection (LFD), Reversible mode of operation
    
    KFD2-ST3-Ex1.LB
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-ST3-Ex2
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC4-Ex1.2O-Y1
    SMART Transmitter Power Supply, Output Current Sink
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
    
    KFD2-STC4-Ex2-Y1
    SMART Transmitter Power Supply, Output Current Sink
    2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA ... 20 mA current sink, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-2
    SMART Transmitter Power Supply
    2-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-Ex1.H
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, High field voltage 17 V DC, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STV4-Ex1.2O-1
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
    
    KFD2-UFC-1.D
    Frequency Converter with Trip Values
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz ... 10 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-UT2-1
    Universal Temperature Converter
    1-channel ** conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-UT2-2
    Universal Temperature Converter
    2-channel ** conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as ** splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-VR-Ex1.18
    Voltage Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 12 V, Voltage output 0 V ... 12 V, Transfer direction: to the control system
    
    KFD2-VR2-Ex1.50M
    Voltage Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV ... ± 50 mV, Voltage output 0 mV ... ± 50 mV, Selectable up/downscale sensor breakage detection, Transfer direction: to the control system
    
    KFD2-WAC2-1.D
    Strain Gauge Converter
    1-channel ** conditioner, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware or keypad, RS-485 interface, Line fault detection (LFD)
    
    KFD0-CS-Ex1.52
    Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Transfer direction: to the control system
    
    KFD0-CS-Ex2.52
    Repeater
    2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Transfer direction: to the control system
    
    KFD0-CS-Ex2.54
    Repeater
    2-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC 61508, Transfer direction: to the control system
    
    KFD0-TT-1
    Thermocouple Converter
    1-channel ** conditioner, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges
    
    KFD2-ER-2.W.LB
    Conductivity Switch Amplifier
    2-channel ** conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)
    
    KFD2-HLC-Ex1.D.2W
    HART Loop Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as ** splitter (1 input and several outputs), 2 relay contact outputs (change-over contacts), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad
    
    KFD2-PT2-Ex1-1
    Potentiometer Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 5 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508
    
    KFD2-PT2-Ex1-4
    Potentiometer Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 0 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SR2-Ex2.W.SM
    Standstill and Rotational Direction Monitor
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Selectable frequency trip values, 2 relay contact outputs, Start-up override, Selectable mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC3-Ex1
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitter, Output 4 mA ... 20 mA, SMART capable up to 40 kHz (-1dB), Suitable for Honeywell DE protocol, Terminals with test points
    
    KFD2-UFT-Ex2.D
    Frequency Converter with Direction and Synchronization Monitor
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD)
    
    KFD2-UT2-Ex1-1
    Universal Temperature Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-VM-Ex1.35.L
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Output 15.3 V DC at 17 mA, 3 logic inputs with AND/OR logic, Service port for isolator function test, Input: with prelogic
    
    KFD2-WAC2-Ex1.D
    Strain Gauge Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware or keypad, RS-485 interface, Line fault detection (LFD)
    
    KFD0-CS-Ex1.54-Y2
    Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Transfer direction: to the control system
    
    KFD0-CS-Ex2.50P
    Repeater
    2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-LGH
    Place Holder Barrier
    IS K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers
    
    KFD0-LGH-5T
    Place Holder Barrier
    IS K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers, Two additional green terminal blocks supplied separately
    
    KFD0-LGH-GN
    Place Holder Barrier
    IS K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers
    
    KFD0-LGH-Y34868
    Place Holder Barrier
    Non-IS K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, No electrical function: empty housing
    
    KFD0-LGH-Y39343
    Place Holder Barrier
    IS K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via DIP switches and plug-in jumpers
    
    KFD0-RO-2
    Relay Module
    2-channel ** conditioner, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. to IEC 61508
    
    KFD0-RSH-1.1D.F1
    Relay Module
    SGM7G-09A7C6C
    SGM7G-09A7C61
    SGM7G-09AFC6C
    SGM7G-09AFC61
    SGM7G-20A7C6C
    SGM7G-20A7C61
    SGM7G-20AFC6C
    SGM7G-20AFC61
    SGM7G-30A7C6C
    SGM7G-30A7C61
    SGM7G-30AFC6C
    SGM7G-30AFC61
    SGM7G-44A7C61
    SGM7G-44AFC6C
    

    http://chuangfusy.b2b168.com
    欢迎来到上海创弗实业有限公司网站, 具体地址是上海市松江区方松街道辰塔路2号,联系人是张晓龙。 主要经营上海创弗实业有限公司,公司业务范围涉及:工厂自动化产品销售、过程自动化控制仪表,阀门,仪器仪表,传感器,安全栅,技术咨询、技术服务,承接过程仪表控制项目罗斯蒙特ROSEMOUNT变送器, 液位产品系列罗斯蒙特分析仪变送器和传感器施克/西克SICK传感器、倍加福P+F安全栅,倍加福传感器,IFM易福门传感器,TURCK图尔克传感器,FESTO费斯托,MTS传感器等自动化产MTL安全栅。 单位注册资金单位注册资金人民币 100 万元以下。 价格战,是很多行业都有过的恶性竞争,不少厂家为了在价格战役中获胜,不惜以牺牲产品质量为代价,而我们公司坚决杜绝价格战,坚持用优质的原材料及先进的技术确保产品质量,确保消费者的合法利益。