HD2-FBPS-1.500倍加福HD2-DM-A.RO

F.MIO.P12.*12.P.*.***.***.**00
Multi-Input/Output Junction Box, Polyester (GRP)
For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA

F.MIO.S12.*12.P.*.***.***.**00
Multi-Input/Output Junction Box, Stainless Steel
For discrete inputs and outputs, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA

F.TI0.P12.*08.P.0.***.***.**00
Temperature Multi-Input Junction Box, Polyester (GRP)
8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA

F.TI0.S12.*08.P.0.***.***.**00
Temperature Multi-Input Junction Box, Stainless Steel
8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA

F.VC0.P21.A04.*.*.***.***.*000
Valve Coupler Junction Box, Polyester (GRP)
4 valve control and 8 position feedback **s, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA

F.VC0.S20.A04.*.*.***.***.*000
Valve Coupler Junction Box, Stainless Steel
4 valve control and 8 position feedback **s, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HCD2-FBPS-1.23.500
Fieldbus Power Hub, Compact Power Supply Module

Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HCD2-FBPS-1.500
Fieldbus Power Hub, Compact Power Supply Module

Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HD2-DM-A
Fieldbus Power Hub, Advanced Diagnostic Module

Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HD2-GTR-4PA
PROFIBUS Power Hub, Gateway Module

PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting

KT-MB-GT2AD.FF
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface

System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA

HD2-DM-B
Fieldbus Power Hub, Basic Diagnostic Module
Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HD2-DM-A.RO
Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output
Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HD2-GTR-4PA.PN
PROFINET Power Hub, Gateway Module
Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics

KT-MB-GT2AD.FF.IO
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA

HD2-FBPS-1.500
Fieldbus Power Hub, Power Supply Module
Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-DM-A
Fieldbus Power Hub, Advanced Diagnostic Module

Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA

KT-MB-GT2AD.FF
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface

System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA

FDH-1
Fieldbus Diagnostic Handheld
Fieldbus Diagnostic Handheld, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HD2-DM-A.RO
Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output
Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA

KT-MB-DMA
Advanced Diagnostic Module, Kit for Stand-Alone Operation
Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA

KT-MB-GT2AD.FF.IO
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA

DTM-FC.AD*
Diagnostic Manager
Software
Software user interface for Advanced Diagnostic Modules, Simultaneous access to all ADMs of a plant, Embedded expert system gives pointed advice in clear text, Includes Commissioning Wizard, data historian, oscilloscope..., For FOUNDATION Fieldbus H1 and PROFIBUS PA, Automatic setup of diagnostic system
HD2-FBPS-1.17.500
Fieldbus Power Hub, Power Supply Module
Output: 15 ... 17 V/500 mA, Voltage limitation for FISCO ic, Entity ic, also FNICO and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HD2-FBPS-1.23.500
Fieldbus Power Hub, Power Supply Module
Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HD2-FBPS-1.25.360
Fieldbus Power Hub, Power Supply Module
Output: 25 ... 28 V/360 mA, Universal power supply for most applications, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA

MB-FB-GTR1*
Fieldbus Power Hub, Gateway Motherboard
For 2 gateway modules, For PROFIBUS PA, Redundant configuration, Installation in Zone 2/Class I, Div. 2, Spring terminals or screw terminals selectable

MBHC-FB-4.GT*
Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules
4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics

MBHC-FB-4.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
4 segments, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA

MBHC-FB-4R.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
4 segments, redundant, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
F2D0-MIO-Ex12.PA.*
Multi-Input/Output Device with Aluminum Housing
For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA

F2D0-TI-Ex8.PA.*
Temperature Multi-Input Device with Aluminum Housing
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA

R8D0-MIO-Ex12.PA*
Multi-Input/Output Device for Cabinet Installation
For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA

RD0-TI-Ex8.PA.*
Temperature Multi-Input Device for Cabinet Installation
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA