公司动态

当前所在位置:网站首页 > 公司动态

F2D0-FB-Ex4.*

HCD2-FBPS-1.23.500
Fieldbus Power Hub, Compact Power Supply Module

Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB0.P**.A**.1.0.***.***.****
FieldBarrier Junction Box, Polyester (GRP)
4, 8 or 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA

F.FB0.S**.A**.1.0.***.***.****
FieldBarrier Junction Box, Stainless Steel
4, 8 or 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA

F.FB1.P14.A**.1.*.***.***.****
FieldBarrier Junction Box, Polyester (GRP)
8, 10, 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA

F.FB1.S14.A**.1.*.***.***.****
FieldBarrier Junction Box, Stainless Steel
8, 10, 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA

F2D0-FB-Ex4.*
FieldBarrier®
4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA

R4D0-FB-IA*
FieldBarrier® for Cabinet Installation
FieldConnex® FieldBarrier®, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA

RD0-FB-Ex4.*
FieldBarrier®
4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HCD2-FBPS-1.500
Fieldbus Power Hub, Compact Power Supply Module

Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HD2-DM-A
Fieldbus Power Hub, Advanced Diagnostic Module

Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HD2-GTR-4PA
PROFIBUS Power Hub, Gateway Module

PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting

KT-MB-GT2AD.FF
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface

System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA
KFD2-BR-1.PA.1500
Basic Segment Coupler
Output: 24 ... 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting

KFD2-BR-Ex1.3PA.93
Segment Coupler 1
Output: 12.6 ... 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator

KLD2-PR-1.IEC
Fieldbus Power Repeater
Output: 24 ... 26 V/400 mA, For extension of fieldbus segments, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA

KLD2-PR-Ex1.IEC1
Fieldbus Power Repeater
Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to FISCO, 100 mA supply of the field side, Improves the fieldbus **, Extension of the transmission distance by means of opening a new fieldbus segment

KLD2-PR-Ex1.IEC
Fieldbus Power Repeater
Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to Entity, 70 mA supply of the field side, Improves the fieldbus **, Extension of the transmission distance by means of opening a new fieldbus segment
HD2-DM-B
Fieldbus Power Hub, Basic Diagnostic Module
Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HD2-DM-A.RO
Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output
Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA

HD2-GTR-4PA.PN
PROFINET Power Hub, Gateway Module
Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics

KT-MB-GT2AD.FF.IO
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA

HD2-FBPS-1.500
Fieldbus Power Hub, Power Supply Module
Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KFA6-STR-1.24.500
Power Supply

115/230 V AC supply, Output 24 V DC, 500 mA, Electronic short circuit protection, Power Rail connection

KFD2-EB2.R4A.B
Redundant Power Feed Module

Interface for Power Rail, Used for redundant configuration, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication

KFD2-EB2
Power Feed Module
Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication

PR-03
Power Rail
Alternative power supply, Nominal current 4 A, Simple installation, Standard length 50 cm, can be shortened to any length in 4 cm steps, Terminating insulation by end cap, included in the delivery package, With 2 leads for voltage supply and 1 lead for centralized error messages

UPR-03
Universal Power Rail
35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 2 m (6 foot), simple to customize to application space, Eliminates daisy-chains

UPR-03-S
Universal Power Rail
35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 0.8 m (2.6 ft), simple to customize to application space, Eliminates daisy-chains

UPR-E
End Cap for Universal Power Rail
Termination of DIN mounting rail, Suitable for Power Rail UPR-**-*, Suitable for profile rail K-DUCT

K-DUCT-BU
Profile Rail
Cable trunking is integrated in the mounting profile, Safe spacious separation of safe and hazardous **s, No additional cable guides necessary, Standard length 1.8 m (5.8 ft), simple to customize to application space, With mounting aids

K-DUCT-BU-UPR-03
Profile Rail
Cable trunking with integrated Power Rail UPR-03, Safe spacious separation of safe and hazardous **s, No additional cable guides necessary, Provides DC supply voltage to all equipped K-System modules, Standard length 1.8 m (5.8 ft), simple to customize to application space, With end caps UPR-E, cover and mounting aids

K-DUCT-BU-UPR-05
Profile Rail
Cable trunking with integrated Power Rail UPR-05, Safe spacious separation of safe and hazardous **s, No additional cable guides necessary, Provides DC supply voltage and the bus connection to all equipped K-System modules, Standard length 1.8 m (5.8 ft), simple to customize to application space, With end caps UPR-E, cover and mounting aids

K-MS
Mounting Socket
1-channel, KF module DIN rail isolation block, Snaps on to 35 mm DIN rail acc. to EN 60715, Easy panel mounting

KFA6-STR-1.24.4
Power Supply
115/230 V AC supply, Output 24 V DC, 4 A, Fused output, Power Rail connection

KFD2-EB2.R4A.B.SP
Redundant Power Feed Module
Interface for Power Rail, Used for redundant configuration, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication, Connection via spring terminals with push-in connection technology

KFD2-EB2.SP
Power Feed Module
Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication, Connection via spring terminals with push-in connection technology

PR-05
Power Rail
Alternative power supply, Nominal current 4 A, Simple installation, Standard length 50 cm, can be shortened to any length in 4 cm steps, Terminating insulation by end cap, included in the delivery package, With 2 leads for power supply, 2 leads for bus connections and 1 lead for centralised error messages or HART ** transfer (with RPI-system)

UPR-03-M
Universal Power Rail
35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 1.6 m (5 foot), simple to customize to application space, Eliminates daisy-chains

UPR-05
Universal Power Rail
35 mm DIN mounting rail with 5-conductor insert, Provides DC supply voltage and the bus connection to all equipped K-System modules, Standard length 2 m (6 foot), simple to customize to application space, Eliminates daisy-chains

UPR-05-S
Universal Power Rail
35 mm DIN mounting rail with 5-conductor insert, Provides DC supply voltage and the bus connection to all equipped K-System modules, Standard length 0.8 m (2.6 ft), simple to customize to application space, Eliminates daisy-chains

UPR-COVER
Cover for DIN Mounting Rail
Cover for DIN mounting rail, Suitable for 35 mm DIN mounting rail UPR-MR, Suitable for Power Rail UPR-**-*, Suitable for profile rail K-DUCT, Standard length 0.8 m (2.6 ft), simple to customize to application space, Packaging unit: 2 pieces

UPR-I
Insulation Spacer for Universal Power Rail
Electrical insulation of segmented Power Rail inserts, Suitable for Power Rail UPR-**-*, Suitable for profile rail K-DUCT

UPR-INS-03
Insert for DIN Mounting Rail
3-conductor insert in 35 mm DIN mounting rail, Suitable for 35 mm DIN mounting rail UPR-MR, Suitable for profile rail K-DUCT, Standard length 2 m (6 foot), simple to customize to application space

UPR-MR
DIN mounting rail
35 mm DIN mounting rail acc. to EN 60715:2001, Standard length 2 m (6 foot), simple to customize to application space, Slot for insert UPR-INS-**, Packaging unit: 2 pieces

K-DUCT-GY
Profile Rail
Cable trunking is integrated in the mounting profile, Safe spacious separation of field and control **s, No additional cable guides necessary, Standard length 1.8 m (5.8 ft), simple to customize to application space, With mounting aids

K-DUCT-GY-UPR-03
Profile Rail
Cable trunking with integrated Power Rail UPR-03, Safe spacious separation of field and control **s, No additional cable guides necessary, Provides DC supply voltage to all equipped K-System modules, Standard length 1.8 m (5.8 ft), simple to customize to application space, With end caps UPR-E, cover and mounting aids

K-DUCT-GY-UPR-05
Profile Rail
Cable trunking with integrated Power Rail UPR-05, Safe spacious separation of field and control **s, No additional cable guides necessary, Provides DC supply voltage and the bus connection to all equipped K-System modules, Standard length 1.8 m (5.8 ft), simple to customize to application space, With end caps UPR-E, cover and mounting aids

UPR-INS-05
Insert for DIN Mounting Rail
5-conductor insert in 35 mm DIN mounting rail, Suitable for 35 mm DIN mounting rail UPR-MR, Suitable for profile rail K-DUCT, Standard length 2 m (6 foot), simple to customize to application space

chuangfusy.b2b168.com/m/