公司动态

当前所在位置:网站首页 > 公司动态

KFD2-SR3-2.2S倍加福KCD2-SR-1.LB

KFD2-SR3-2.2S倍加福KCD2-SR-1.LB

KCD2-SR-1.LB  KFD2-SR3-2.2S倍加福KCD2-SR-1.LB
Switch Amplifier

1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508

KCD2-SR-2
Switch Amplifier
2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508

KFA6-ER-1.6
Conductivity Switch Amplifier
1-channel ** conditioner, 230 V AC supply, Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Relay contact output, Minimum/maximum control

KFD2-ER-1.6
Conductivity Switch Amplifier
1-channel ** conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Relay contact output, Minimum/maximum control

KCD2-SOT-1.LB
Switch Amplifier
1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508

KFA6-SR-2.3L
Switch Amplifier
2-channel ** conditioner, 115/230 V AC supply, 3-wire PNP/NPN sensor or push-pull input, Relay contact output, DIP switch selectable functions, Minimum/maximum control, Up to SIL 2 acc. to IEC 61508

KFA6-SR-2.3L.FA
Switch Amplifier
2-channel, 115/230 V AC supply, 3-wire PNP/NPN sensor or push-pull input, Relay contact output, DIP switch selectable functions, Minimum/maximum control, Up to SIL 2 acc. to IEC 61508

KFD2-ER-2.W.LB
Conductivity Switch Amplifier
2-channel ** conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)

KFU8-SR-1.3L.V
Switch Amplifier, Timer Relay
1-channel ** conditioner, Universal usage at different power supplies, 3-wire PNP/NPN sensor or push-pull input, 2 relay contact outputs, Adjustable energized/de-energized delay

KCD2-SOT-2
Switch Amplifier
2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508

KCD2-SR-1.LB.SP
Switch Amplifier
1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508

KCD2-ST-1.LB
Switch Amplifier
1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508

KCD2-ST-2
Switch Amplifier
2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508

KFA5-ER-1.W.LB
Conductivity Switch Amplifier
1-channel ** conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)

KFA6-ER-1.5
Conductivity Switch Amplifier
1-channel ** conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Relay contact output, Minimum/maximum control

KFA6-ER-1.W.LB
Conductivity Switch Amplifier
1-channel ** conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)

KFA6-ER-2.W.LB
Conductivity Switch Amplifier
2-channel ** conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)

KFD2-ER-1.5
Conductivity Switch Amplifier
1-channel ** conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Relay contact output, Minimum/maximum control

KFD2-ER-1.W.LB
Conductivity Switch Amplifier
1-channel ** conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)

KFD2-SR3-2.2S
Switch Amplifier
2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511

KCD2-SOT-1.LB.SP
Switch Amplifier
1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508

KCD2-SOT-2.SP
Switch Amplifier
2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508

KCD2-SR-2.SP
Switch Amplifier
2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508

KCD2-ST-1.LB.SP
Switch Amplifier
1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508

KCD2-ST-2.SP
Switch Amplifier
2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508

KFD2-SR2-2.2S
Switch Amplifier
2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511

chuangfusy.b2b168.com/m/

返回目录页